IMPORTANT ....
PLEASE READ
"ULTIMIX" dispenses BOILING water Please treat with care.
Do not use the "ULTIMIX" for washing hands
IMPORTANT:
An authorised plumber must install units unit must be connected in
accordance with
AS3500.4.1 or, AS/NZS 3500.4.2
Supply pressure minimum 200 Kpa, maximum 2000 Kpa
Supply temperature 5 deg to 35 deg
This unit is fitted with a computerised element and boil dry protection.
Altitude will alter temperature (refer back to manufacturer)
DO NOT
SWITCH ON POWER UNTIL WATER RUNS OUT OF TAP
|
* Rapid action Ό turn tap handles
|
* No drainage or overflow is required |
|
* The tap vents through the tap spout |
Components supplied with the unit;
-
Chiller unit
-
Boiling water unit
-
Tap dispenser
-
Auquknect flexible connector 450mm long (Do not over tighten)
-
Combined dual check valve with 350 Kpa PLV (Connected to boiling
water unit)
-
Filter enclosed in the boiling water case.
* If fitted with filter we recommendchanging the cartridge every
6 months
* The manufacturer recommends the cleaning and service of the unit every 12
months
* IF SUPPLIED CORD IS DAMAGED IT MUST BE REPLACED BY AN AUTHORISED SERVICE AGENT
(ELECTRICIAN).
PLEASE LEAVE THESE INSTRUCTIONS WITH THE OWNER.
Installation
Instructions ULTIMIX
DO NOT PLUG
IN OR TURN ON POWER UNIT MUST BE POSITIVELY EARTHED
- Position the tap head on a flat area in an appropriate location (i.e. Tea
room sink), Drill 38mm diameter hole, washer supplied.
- Position boiling water unit underneath the sink directly beneath the tap
head.
- Observe attached labels (ensure when pipes are cut de burr ends before
fitting).
- Connect 5/16 outlet from the tap head spout to the boiling water unit, NB:
The pipe must not be extended and must have continuous fall between tap and
boiling water unit.
- Connect inlet pipe from the tap body to the boiling water unit (inlet).
- Connect main water supply from the tap body to the outlet side of the filter
head.
- Connect the 3/16 nylon tube from the tap to the 3/16 copper vent pipe on
the boiling water unit. (heat nylon tube ends in boiling water to ensure easier
fitting).
- Position the chiller unit adjacent to the boiling water unit with a minimum
clearance between the units of no less than 50mm.
- Connect inlet and outlet pipes from the tap head to chiller unit as per
markings.
- Connect aquaknect flexible hose to PLV (inlet side of the filter head).
- Open both taps until the water is flowing from both spouts. 18 litres of
water must be flushed through filter before turning on power.
- Plug units into the power point and switch on.
NB: When fitting this unit in a cupboard of small
proportion, please note that these units omit heat. If in doubt install cross
flow vents.
Do not connect to hot water line to do so will void warranty.
|
TYPICAL INSTALLATION |
|

|
|
UNDERSIDE OF TAP |
|

|
Trouble
Shooting
Action only to be performed by a qualified person.
BOILING WATER UNIT
| SYMPTOM |
CAUSES |
ACTION |
| No Water
|
Water supply turned off |
Check mains supply |
| Blocked Filter |
Replace Cartridges |
| Water not hot
|
Faulty element and computer |
Replace dual computerised element |
| No power supply |
Check and test power supply |
| Water overflowing from tap spout
|
Expansion chamber full |
Run tap for 5 10 mins, this will correct water
level in expansion tank. |
| Low inlet pressure |
Contact manufacturer |
| Boiling On |
Replace element |
| Excessive steam from tap
|
Fault element |
Replace element |
| The boiling water unit
is designed to have no less than 150ml off at any one time. |
CHILLER UNIT
| SYMPTOM |
CAUSES |
ACTION |
| No water |
Water supply turned off |
Check mains supply |
| Blocked Filter |
Replace cartridges |
| Water not cold |
Thermostat |
Not set correctly |
| Loss of gas |
Contact manufacturer |
| Failed fan |
Contact manufacturer |
| No power supply |
Check and test power supply |
| Poor ventilation |
Clean cabinet louvers (if fitted) & condenser fins.
These units need ventilation. |
| Faulty element |
Replace element |
|