IMPORTANT ....
PLEASE READ
This undersink BOILING BILLY dispenses BOILING water –
Please treat with care.
Do not use the undersink BOILING BILLY for washing hands
|
Do not regulate water flow with the tap. Have your plumber
install a pressure limiting vale if pressure exceeds manufacturers
recommendations (350Kpa). |
|
|
|
For areas with pressure above 350 Kpa, an authorised 350 Kpa
only pressure limiting valve must be fitted for maximum efficiency. |
|
IMPORTANT:
THIS UNIT MUST BE INSTALLED BY AN AUTHORISED PLUMBER.
|
*Maximum inlet pressure 350 Kpa
|
*Minimum inlet pressure 250 Kpa |
This unit is fitted with a computerised element and boil dry
protection. The computer is set at 97°, altitude will alter temperature (refer
to manufacturer).
WARNING: A backflow prevention device complying with the
requirement of A.S. 3500 I is required to be installed on the water supply inlet
to this unit.
DO NOT SWITCH ON POWER WITHOUT WATER RUNNING OUT FROM THE TAP.
-
Unit to be connected in accordance with AS3500.4.1 or AS/NZS
3500.4.2
-
If fitted with filter we recommend changing the cartridge every
6 months
-
The manufacture recommends the cleaning and service of the unit
every 12 months
-
IF SUPPLIED CORD IS DAMAGED IT MUST BE REPLACED BY AN AUTHORISED
SERVICE AGENT (ELECTRICIAN).
PLEASE LEAVE THESE INSTRUCTIONS WITH THE OWNER.
Installation Instructions
MODEL TD SERIES UNDERSINK
DO NOT PLUG IN
OR TURN ON POWER
| 1. Position heater unit underneath the sink as close as possible
to its outlet tap.

3. OBSERVING THE ATTACHED LABELS
- Measure and cut pipes to desired length.
- Connect the ¼” pipe from the tap to the inlet of the heater.
- Connect the 5/16” pipe from the tap to the outlet of the heater.
- Connect the ¼” pipe from the tap to the water supply via an approved back
flow device.
- Connect the flexible tubing from the tap to the vent pipe of the heater.
(Place the end of the flexible tube in hot water and then push onto the copper.

|

2. Position the tap in the desired location. Drill 35mm hole.

4. All pipes and tubes must not be extended and must have a continuous
fall between tap and heater. 5. OPEN TAP UNTIL WATER IS FLOWING FROM
THE SPOUT. 6. Plug unit into power point and switch on. |
UNIT MUST
BE POSITIVELY EARTHED
Before using we recommend the fitting of a
water filter.
Only Teflon tape to be used where necessary.
Under no circumstances is plumber’s paste to be used.

TYPICAL
INSTALLATION
N.B. When fitting this unit in a cupboard of small proportions, please note that
the unit does omit heat.
If in doubt fit cross flow vents.
DO NOT connect to hot water line – to do so will void
warranty.
AFTER POWER IS ON – allow 30 minutes before using.
Trouble
Shooting
Action only to be performed by a qualified person.
| SYMPTOM |
CAUSES |
ACTION |
No Water
|
Water supply turned off |
Check mains supply. |
| Blocked filter |
|
Water not hot
|
Faulty element |
Replace element |
| No power supply |
Check and test power supply |
Water overflowing from tap spout
|
Expansion Chamber full |
Run tap for 5-10 minutes |
| Low inlet pressure |
Contact Manufacturer |
| Excessive steam from tap |
Faulty element |
Replace element |
N.B. These units are designed to have no less than 100ml of
boiling water taken off at a time.
|