This unit dispenses boiling
water Please treat with care.
If a tundish is to be used, it must be placed in accordance with your
plumbing authorities regulations.
IMPORTANT: THIS UNIT MUST BE
INSTALLED BY AN AUTHORISED PLUMBER.
WARNING:
Unit is to be connected in accordance with AS3500.4.1 or AS/NZS 3500.4.2
|
This unit (Boiling waterside) is fitted with
aComputerised elementand boil dryprotections. |
|
|
|
The unit is fitted with a350 kpa pressurelimiting valve with
dualcheck. |
|
DO NOT PLUG IN POWER MUST BE OFF UNTIL
INSTALLATION IS
COMPLETED
IF FITTED WITH FILTER WE RECOMMEND CHANGING THE CARTRIDGE EVERY 6 MONTHS.
THE MANUFACTURER RECOMMENDS THE CLEANING AND SERVICEOF THE UNIT EVERY 12
MONTHS.
N.B. MUST ALLOW 150MM ABOVE AND BELOW FOR AIR FLOW.
IF SUPPLIED CORD IS DAMAGED IT MUST BE REPLACED BY AN AUTHORISED SERVICE AGENT
(ELECTRICIAN).
PLEASE LEAVE THESE INSTRUCTIONS WITH THE
OWNER.
Installation Instructions MODEL MBC SERIES
DO NOT PLUG IN OR TURN ON POWER
-
Remove four screws from plastic case and remove cover.
-
Mount unit on the wall using fixing points on the back of the
unit. Unit is to be positioned 300-350mm above a drain board when possible, so
that in the event of filling cups, etc. spillage occurs, water is disposed via
sink.
-
Connect cold water supply to inlet (12mm) through a stop tap
in the supply line. (Stop tap to be supplied by the installer). Provision is
made for concealed plumbing or out of the bottom of the unit.
-
Connect overflow pipe to waste (12mm). Check with plumbing
regulations in your state. Do not block the overflow pipe.
-
Place plastic cover back onto the unit and secure with the
four screws.
-
Fit red handle tap onto the left hand side inlet (boiling
water) and the black handle tap onto right side inlet (chilled water).
-
Plug unit into 10amp power inlet (do not turn on the power).
-
Turn on water supply to the unit and open the red handle
tap only until water flows out of the tap. If fitted with internal filter flush
18 litres of water through unit.
-
When the water flows out of the red handle tap and the
chiller tap, please switch the power on.
ALLOW APPROX. 30 MINUTES
BEFORE USE
Please note: The boiling water
unit is fitted with a computerised element and boil dry protection the computer
is set at 97 degree C, altitude will alter temperature (refer to manufacturer).
Only Teflon tape to be used
where necessary, under no circumstances is plumbers paste to be used.
Do not connect to hot water line
to do so will void warranty.
MR PLUMBER:
DEPENDING ON WATER CONDITIONS
THE MBC MAY REQUIRE AN ADDITIONAL PRE FILTERS (CONTACT MANUFACTURER)
TROUBLE SHOOTING
Action to be performed
by a qualified person.
CHILLED UNIT
| SYMPTOM |
CAUSES |
ACTION |
| Water overflowing |
Water level too high |
Check and set approx 20mm. Below the
overflow pipe inside the flow tank. Remove ball valve body and Insert, clean and
reinstall and Adjust ball valve arm if necessary. Remove ball valve float and
Check to ensure that there is no water in it. Replace if necessary. Ensure ball
valve closes (does not leak) |
| Not cold |
Power not on |
Check if power is turned on. |
| |
Faulty thermostat |
Contact service agent or
Manufacturer. |
| |
Faulty compressor |
Contact service agent or
Manufacturer. |
| |
Loss of Gas |
Contact Manufacturer. |
| |
Poor ventilation |
Clean cabinet louvers (if fitted)
and condenser fins (located under fan). The unit must have ventilation |
| No water |
Water has been turned off
|
Turn on water |
| |
Blocked ball valve |
Remove ball valve and clean or
replace if necessary. |
| |
Blocked filter |
Replace if necessary. |
| |
Faulty thermostat |
Check to ensure that thermostat has
not been turned to cold all the way, this will freeze the unit. |
|
RATING CONDITIONS PERFORMANCE
Inlet water temperature 27 degree C
Outlet water temperature 10 degree C
Ambient water temperature 27 degree C
All units set at approx. 6 degree C |
TROUBLE SHOOTING
Action to be performed
by a qualified person.
BOILING WATER UNIT
| SYMPTOM |
CAUSES |
ACTION |
Water
overflowing |
Water level too high |
Check and set approx 20mm.Below the
overflow pipe inside the flow tank. (Bend arm if necessary)
Remove ball valve body and Insert, clean and reinstall and Adjust ball valve arm
ifnecessary.
Remove ball valve float and check to ensure that there is no water in it.
Replace if necessary. |
| Continuous Boiling |
Ball valve defective |
Ensure ball valve closes off. |
| |
Faulty element |
Replace element |
| Water is not hot |
Power not on |
Check if power is on. |
| |
Element Faulty |
Replace element. |
| |
Water has been turned off
|
Turn on water. |
| |
Blocked ball valve |
Remove ball valve and clean out or
replace if necessary. |
| No water |
Blocked flow tank (hole)
|
Remove arm and ball float from the
flow tank and using 3mm diam wire clean out the hole situated near the bottom of
the flow tank. |
| |
Blocked filter |
Change filter cartridge. |
|